BGHPN - SAFETY-SILV 1200
- MSDS: BGHPN
- Manufacturer: JW HARRIS CO INC
- Product Name: SAFETY-SILV 1200
- National Stock Number: 3439-01-046-3655
Product Identification
Product ID:SAFETY-SILV 1200
MSDS Date:10/01/1992
FSC:3439
NIIN:01-046-3655
MSDS Number: BGHPN
Responsible Party
CINCINNATI, OH 45242
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 513-891-2000
Cage: HO350
Contractor
Telephone: 513-891-2000
Cage: HO350
Ingredients
SILVER (SARA 313) (CERCLA)
CAS: 7440-22-4
RTECS: VW3500000
Fraction By Weight: 56%
OSHA PEL 0.01 MG/M3
ACGIH TLV: 0.1 MG/M3
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
COPPER (SARA 313) (CERCLA)
CAS: 7440-50-8
RTECS: GL5325000
Fraction By Weight: 22%
OSHA PEL 0.1MG/M3 FUME;1 DUST
ACGIH TLV: 0.2 MG/M3 FUME
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ZINC OXIDE (SARA 313) (CERCLA)
CAS: 1314-13-2
RTECS: ZH4810000
Fraction By Weight: 17%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
TIN
CAS: 7440-31-5
RTECS: XP7320000
Fraction By Weight: 5%
OSHA PEL 2 MG/M3
ACGIH TLV: 2 MG/M3
BORATE (1-), TETRAFLUORO-, POTASSIUM; (POTASSIUM FLUOBORATE
CAS: 14075-53-7
RTECS: ED2800000
OSHA PEL N/K
ACGIH TLV: N/K
POTASSIUM METABORATE; (BORIC ACID)
CAS: 11113-50-1
OSHA PEL 10 MG/M3 BORATE
ACGIH TLV: 5 MG/M3 BORATE
POTASSIUM BORATE; (POTASSIUM TETRABORATE AS BORATES)
CAS: 1332-77-0
OSHA PEL N/K
ACGIH TLV: N/K
W/RESPECT TO FUME PLUME AS WELL AS PRESENCE OF
RTECS: 9999999ZZ
FROM CLEANING & DEGREASING ACTIVITIES). WHEN FILLER
RTECS: 9999999ZZ
ARE DIFFERENT IN PERCENT & FORM FROM LISTED SOLID
RTECS: 9999999ZZ
IN ROD/WIRE ARE IMPORTANT. CONC OF GIVEN FUME/GAS
RTECS: 9999999ZZ
CONC IN FILLER METAL. DECOMP PRODS OF NORM OPERATION
RTECS: 9999999ZZ
OF THE WIRE.
RTECS: 9999999ZZ
EMPLOYEE TO KEEP HIS/HER HEAD OUT OF THE FUMES. SEE
RTECS: 9999999ZZ
& FULL LENGTH FACESHIELD . USE FACESHIELD
RTECS: 9999999ZZ
Z49.1-SECTION 4.2). PROVIDE PROT SCREENS & FLASH
RTECS: 9999999ZZ
INCL WELDER'S GLOVES & PROT FSHLD & MAY
RTECS: 9999999ZZ
WELL AS DARK SUBSTANTIAL CLOTHING.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACTUAL EXPOS SHOULD BE DETERMD BY
MONITORING FUME IN OPERATOR'S BRTHG ZONE. COPPER & ZINC FUME MAY
CAUSE METAL FUME FEVER. SHORT TERM SYMPS MAY INCL METALLIC TASTE IN
MOUTH, DRYNESS/IRRIT OF THROAT FO LLOWED BY COUGH, SHORTNESS OF
BRTH, NAUS, FEVER, BODY ACHES & CHILLS. LONG TERM EXPOS TO WELDING
FUME, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: GASES OR DUST MAY CONTRIBUTE TO PULM
IRRIT OR PNEUMOCONIOSIS. BRAZING ALLOYS ARE FREQUENTLY USED
W/FLUORIDE TYPE FLUX. IF APPLICABLE, FLUX FUME SHOULD BE CONSIDERED
IN EVALUATION OF HAZARDS.
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH IMPAIRED PULMONARY
FUNCTIONS OR ILLNESS MAY HAVE SYMPTOMS EXACERBATED BY FUME
IRRITANTS.
First Aid
First Aid:INGEST: CALL MD IMMEDIATELY . EYES: IMMEDIATELY FLUSH
W/POTABLE WATER FOR A MINIMUM OF 15 MINUTES, SEEK ASSISTANCE FROM
MD . SKIN: FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD . INHAL:
REMOVE FROM DUST OR FUME EXPOSURE. IF BREATHING HAS STOPPED,
PERFORM ARTIFICIAL RESPIRATION. SUMMON MEDICAL AID IMMEDIATELY.
Fire Fighting
Flash Point:NONFLAMMABLE
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:OPEN FLAME AND SPARKS CAN IGNITE
COMBUSTIBLES.
Accidental Release
Spill Release Procedures:NOT APPLICABLE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:READ & UNDERSTAND MFR'S INSTRUCTIONS &
LABEL ON PROD. SEE SNSI/AWS PUBLICATION, "SFTY IN WELDING &
CUTTING" & OSHA 29 CFR 1910 FOR MORE DETAIL.
Other Precautions:ONE REC WAY TO DETERM COMPOSITION & QTY OF FUMES &
GASES TO WHICH WORKERS ARE EXPOS IS TO TAKE AIR SAMPLE IN WORKER'S
BRTHG ZONE. SEE ANSI/AWS F1.1 AVAIL FROM AWS. PRODS ARE SHIPPED
NONHAZ, NONFLAMM, NONEXPLO & NONREACTIVE SOLID MATLS.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRABLE FUME
RESPIRATOR OR AIR SUPPLIED RESPIRATOR WHEN BRAZING IN CONFINED
SPACE OR WHERE LOCAL EXHAUST OR VENTILATION DOES NOT KEEP EXPOSURE
BELOW TLV.
Ventilation:USE ENOUGH VENT, LOC EXHST AT FLAME TO KEEP FUMES & GASES
BELOW TLV'S IN WORKER'S BRTHG ZONE & GEN AREA. TRAIN (ING 14)
Protective Gloves:WELDER'S GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS (ING 15)
Other Protective Equipment:WEAR HEAD & BODY PROT WHICH HELP PVNT INJURY
FROM HEAT, RADIA, SPKS & FLAME. SEE ANSI 149.1. AT MINIMUM THIS
(ING 17)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
HAZ DECOMP PROD: PROCESS, PROC & FILLER METALS USED. OTHER CNDTNS WHICH
INFLUENCE COMPOSITION & QTY OF FUMES & GASES WHICH WORKERS MAY BE
EXPOS INCL: COATING ON METAL BEING BRAZED (SUCH AS PAINT/PLATI
NG/GALVANIZING), NUMBER OF OPERATORS & VOL OF WORK AREA, QUALITY &
AMT OF VENT, POSITION OF OPERATOR'S HEAD (ING 8)
Chemical Properties
HCC:N1
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BRAZING FUMES & GASES CANNOT BE
CLASSIFIED SIMPLY. COMPOSITION & QTY ARE BOTH DEPENDENT ON METAL
BEING BRAZED, (SUPDAT)
Disposal
Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,
STATE AND LOCAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.